Glazpart Link Vent MK II

Agate Grey
Anthracite Grey
Black
Chartwell Green
Cream
Hazy Grey
Irish Oak
Slate Grey
Tan
Agate Grey
Anthracite Grey
Black
Chartwell Green
Cream
Hazy Grey
Irish Oak
Slate Grey
Tan

Glazpart Link Vent MK II

  • Meets Equivalent Air Flow requirements of Document F 2021
  • 10 or 13mm slot heights
  • Full range of colours in moulded plastic, premium woodgrain effect, vacuum foiling or sprayed finishes
  • High decibel ratings particularly in the closed position

More

Description
Downloads
Questions & Answers

The design of the Link Vent MK II benefits from aerodynamic features which direct the air flow efficiently through the vents pathway - the canopy extends only 25mm. It has been developed to meet the minimum requirements of the building regulation Part F1:2021.

Options are available to ensure compliance for both 10mm and 13mm slot height requirements. The design of these vents allow enhanced air flow for their size, meaning in many scenarios, fewer vents are required to rout and fit making installation faster and keeping production costs down.

The vent has one of the highest decibel ratings on the market for a non-acoustic vent. Improved Db reduces noise to new levels of performance, especially in the closed position. The aesthetically pleasing and patented design helps to reduce the visibility of the trickle vent on a window.

It is available in a large range of solid colour or wood grain finishes - internal and external parts can be bought separately for flexible colour choice. The vents are through moulded meaning the colour won’t scratch or peel off. Canopies can be vacuum foiled to match embossed Linear wrapped profiles and the vents can be sprayed to any RAL colour.

The vent has no end caps and is supplied with the fixing clips fitted - you can push fit the vent into place within seconds. The clips automatically centre the vent in the rout, ensuring it is fitted level. If you prefer to screw fix your trickle vents, just pop out the fitted screw caps before fitting and fix as normal.

 

Technical Information:

Link Vent Mk II: 2000

  • Equivalent Area: 2000mm2 EQA
  • Free Area: 2019mm2
  • Acoustic D n,e,w (+/-) - vent open: 35 (0;1)
  • Acoustic D n,e,w (+/-) - vent closed: 40 (-1;-2)
  • Air Leakage: 0.39 m3/h 0.11 L/s
  • Watertightness Test to BS EN 13141-1: Resistant to water penetration using method 1A meeting Class 9A requirement up to and at 600pa in BS EN 12208
  • Db Rating: Airbourne sound insulation to BS EN ISO 10140-1:2016 Annex E and BS EN ISO 10140-2:2010 and single number calculated in accordance with BS EN ISO 717-1:2013

Link Vent Mk II: 2500

  • Equivalent Area: 2500mm2 EQA
  • Free Area: 2512mm2
  • Acoustic D n,e,w (+/-) - vent open: 38(0;1)
  • Acoustic D n,e,w (+/-) - vent closed: 51 (-1;-2)
  • Air Leakage: 0.39 m3/h 0.11 L/s
  • Watertightness Test to BS EN 13141-1: Resistant to water penetration using method 1A meeting Class 9A requirement up to and at 600pa in BS EN 12208
  • Db Rating: Airbourne sound insulation to BS EN ISO 10140-1:2016 Annex E and BS EN ISO 10140-2:2010 and single number calculated in accordance with BS EN ISO 717-1:2013

Link Vent Mk II: 4000

  • Equivalent Area: 4000mm2 EQA
  • Free Area: 3954.4mm2
  • Acoustic D n,e,w (+/-) - vent open: 32 (1;1)
  • Acoustic D n,e,w (+/-) - vent closed: 41 (0;0)
  • Air Leakage: TBC m3/h TBC L/s
  • Watertightness Test to BS EN 13141-1: Resistant to water penetration using method 1A meeting Class 9A requirement up to and at 600pa in BS EN 12208
  • Db Rating: Airbourne sound insulation to BS EN ISO 10140-1:2016 Annex E and BS EN ISO 10140-2:2010 and single number calculated in accordance with BS EN ISO 717-1:2013

Link Vent Mk II: 5000

  • Equivalent Area: 5000mm2 EQA
  • Free Area: 5049mm2
  • Acoustic D n,e,w (+/-) - vent open: 35(0;1)
  • Acoustic D n,e,w (+/-) - vent closed: 43 (0;0)
  • Air Leakage: 1.29 m3/h 0.36 L/s
  • Watertightness Test to BS EN 13141-1: Resistant to water penetration using method 1A meeting Class 9A requirement up to and at 600pa in BS EN 12208
  • DB Rating: Airbourne sound insulation to BS EN ISO 10140-1:2016 Annex E and BS EN ISO 10140-2:2010 and single number calculated in accordance with BS EN ISO 717-1:2013
What are the changes to Part F 2021 for trickle vents?

Approved Document F: 2021

Why are there new Part F regulations?

The Future Homes Standard 2021

  • Government led project: 31% reduction in CO2 by June 2022
  • Includes updates to Part L and Part F regulations
  • Currently applies to installations in England
  • For windows and doors, by 15th June 2022
    • U values reduce from 1.6 to 1.4
    • Expected goal of 0.8 by 2025

What products can I use to comply?

As windows now make homes more airtight, additional ventilation is required to circulate air in living spaces. Options include mechanical ventilation, extractor fans and trickle vents.

Trickle vents are by far the cheapest and most practical solution to achieve the regulations for both new build and replacement markets.

  • New trickle vents are being launched to offer increased equivalent area air flow.
  • Adjustments to slot heights may be needed to achieve the EQA requirements.
  • Carl F Groupco stock compliant vents from Glazpart, Greenwood, RW Simon and Yale.

What are the new regulations?

for dwellings regarding ventilation....

New build and extensions:

  • Habitable Rooms + Kitchens
    • 8000 EQA
    • 10,000 EQA (single story)
  • Non Habitable Rooms + Bathrooms
    • 4000 EQA
    • 5000 EQA (single story)
  • WC's + Utility Rooms
    • No defined EQA but ventilation is recommended to be provided.
  • Open Plan Living Room + Kitchen
    • If the dwelling has a kitchen and living room which are not separate rooms, at least three ventilators of the same area as for other habitable rooms should be provided in the open-plan space.

Replacement Market:

  • Replacing less than 30% of glazing
    • Replacement windows must provide at least the equivalent EQA as the old window.
    • If no ventilation was previously in place, the EQA standard for new build must be adhered to.
  • Replacing more than 30% of glazing
    • Follow the regulations as for new build and extensions when replacing more than 30% of the glazing products.

 

New reporting, compliance and certification required by installers from June 2022.

Always refer to the government regulations, download the full document here: https://www.gov.uk/government/publications/ventilation-approved-document-f

 

 